The water tank is often the last thing anyone thinks about on a villa. The plan, garden and shades all get settled first, and then someone asks where there is space left. The results are familiar a tank the crane can barely reach, a pump humming under a bedroom, a water truck blocking the street with a hose running across the yard.
A precast tank is lifted in once and stays where it lands, so this decision deserves a little care at the start. If you have not yet decided between buried and exposed, read underground vs above-ground tanks first, then come back.
Five questions to ask of any spot
Sketch your plot on paper, mark the spots you are considering, and run each one through these
- Can the crane reach it? On a finished villa the crane usually works from the street, and difficulty grows with distance. See truck and crane access.
- Can the water truck fill it? If you rely on trucks even occasionally, the fill point needs to be near where one can park. The tank itself can sit further away, linked by a pipe. Our truck filling guide explains how.
- Where is the septic tank? Keep the water tank as far from it as the plot allows, particularly if the tank is buried.
- Where will the pump go? It should be near the tank, and it makes noise. Think about which rooms are next door.
- What is above and below? Cables, pipes, paving, trees, shades.
Few locations score well on all five. What you want is a spot that does not fail on the two that cannot be fixed later, usually crane access and septic distance. The rest have workarounds.
The side passage
This is what most people ask about first. The strip beside the wall gets little use and often runs close to the street, which is good for the pump, filling and maintenance.
The catch is width. Measure the clear passage after AC units, meters and anything else that sticks out, not just wall to wall. Then compare it with the narrowest tanks
| Tank | Width | Length | Passage fit |
|---|---|---|---|
| 14 m³ | 2.30 m | 3.55 m | Easiest option for smaller villas |
| 29 m³ long | 2.50 m | 5.00 m | Most water for the width, if you have the length |
| 22 m³ long | 2.70 m | 3.70 m | When length is limited and width allows |
| 24 m³ | 2.90 m | 4.40 m | For wider passages |
Here is something many buyers miss. The 29 m³ long is 20 cm narrower than the 22 m³ long and holds 7 m³ more. The trade-off is 1.30 m of extra length. In a long passage, check that dimension before settling for the smaller tank.
Passages carry their own warnings. A pit there sits between two walls with foundations, so an engineer should decide on distances and side support. Water collecting near the house foundation is a separate problem to design out. And an above-ground tank up to 3.30 m tall can block light and air from any window facing the passage.
The back yard
You get space and privacy, the tank stays out of sight from the street, and there are usually fewer services in the ground. For family life it is often the nicest answer.
It is also the furthest point from both crane and truck. On a finished villa the tank may have to travel over the wall or the house, and reach gets harder with distance. Confirm the crane can work from a rear or side street before anything else. Plots with two street frontages have a real advantage here.
If access is fine, the truck does not need to come in. A fill pipe from the front of the villa to the tank, ending in a clean lockable point, keeps hoses out of the house entirely. Details are in tank plumbing connections.
The front yard
Operationally this tends to be the easiest spot. Crane and truck are close, mains water usually enters on this side, and future maintenance is simple.
The downside is appearance and space, as the front yard is your entrance and probably your parking too. That is why most people choosing the front go underground, keeping a tidy surface above with the opening visible and protected.
Think carefully about cars. Do not assume vehicles can drive over or alongside a buried tank. Moving loads are an engineering matter, so if this is the only workable location, have it reviewed before the pit is dug. If cars are not needed there, mark clear limits so nobody drives across it by accident, and keep the opening easy to reach.
Under the garden
Lovely on paper the tank vanishes and you get the space back. It works, with conditions. The opening must stay above ground level, never under soil or planting, and irrigation water must not pool around it and find its way in.
Tree roots go looking for moisture and they travel, so keep strong-rooted trees away from the tank and its pipes, and plant lightly over the top. The tank has a bitumen layer outside and a water-safe chemical lining inside, but there is still no reason to soak the ground around it. Our article on bitumen waterproofing explains how those layers work. Also think about how the opening will look in the middle of your landscaping.
Beside the annex or service room
Many villas have an annex, laundry or pump room. Placing the tank near it collects noise, maintenance and plumbing into one zone, away from the majlis and bedrooms. It deals with pump noise at the root, which no amount of insulation does as well.
Two things to check. Is this also where the septic tank is? Plans often group services on one side, so the separation has to be measured rather than assumed. And does the annex itself stand in the crane's lifting path? For pump selection and placement, see the tank pump guide.
Why not the roof?
People used to light rooftop tanks ask this reasonably enough. A concrete tank is not made for a villa roof. It is heavy when empty, then adds tens of tonnes of water. A small rooftop tank can still have a role in your pressure setup, fed by pump from the concrete tank below. For comparisons between materials, read concrete vs plastic and concrete vs fiberglass.
Positions side by side
| Position | Crane | Water truck | Watch out for |
|---|---|---|---|
| Side passage | Usually good | Good | Width, nearby foundations |
| Back yard | Harder | Needs a long fill pipe | Crane reach, house height |
| Front yard | Easiest | Easiest | Appearance, car movement |
| Under garden | Depends | Depends | Irrigation, roots, the opening |
| Near annex | Depends | Depends | Septic distance |
Sizing and position are one decision
Use the calculator or the rule behind it people × daily use × days. At an average of 250 litres per person per day
| Household | Daily use | 14 m³ | 22 m³ | 29 m³ |
|---|---|---|---|---|
| 6 people | 1,500 litres | 9.3 days | 14.7 days | 19.3 days |
| 10 people | 2,500 litres | 5.6 days | 8.8 days | 11.6 days |
| 15 people | 3,750 litres | 3.7 days | 5.9 days | 7.7 days |
A big garden, a pool and frequent guests push use higher, so the calculator also has a 350 litre option. Fifteen people at that rate use 5,250 litres a day, and a 29 m³ tank then lasts about 5.5 days. The size guide goes through this in full.
If no single big tank fits, you do not have to give up capacity. Several tanks can be installed and connected, which suits palaces and large villas whose spaces are split across the plot. See the villa water tank page for more.
New build or finished villa?
Under construction. This is the best moment. Fix the position on the drawings with your engineer before services are finalised. Make the fill point and pump line part of the design. Install the tank before the wall closes, or leave a route for the crane. Excavating alongside the villa foundations can also be coordinated more easily.
Finished and lived in. Reality decides. Start from wherever the crane can reach, then investigate below ground. If the spot is paved, include re-paving in your plans. Keep the work area closed off from children and plan around the household. Preparing the site sets out the sequence.
Coast, mountains and in between
Region affects position too. On coastal plots in Jeddah, Dammam or Jubail, shallow groundwater is more likely, which can make an above-ground position better even if you would prefer to bury the tank. See high groundwater.
On sloping or rocky plots around Abha and Taif, a lower part of the land might help with filling, but crane access comes first. In Riyadh, truck access and available space tend to dominate. We cover all regions of the Kingdom.
Mistakes worth avoiding
- Choosing the spot from a drawing without checking cables overhead.
- Measuring a passage wall to wall and forgetting the AC units.
- Leaving no easy way to reach the opening for inspection and cleaning.
- Putting the pump beside a bedroom or majlis.
- Running an overflow with nowhere to drain.
- Judging a location while it is empty, without picturing machinery working there.
How to finish the decision
Pick your two or three best spots. Photograph each from inside the plot, and photograph the street as well. Note the size you have in mind and send it all to us on WhatsApp along with the villa location. You get a written quote and a date in reply. The tank carries a 10-year warranty on manufacturing and installation, covering cracks and leaks. You can also browse all tank sizes before you get in touch.