When the crane sets your tank down, it is tempting to feel the job is finished. It is not. The connections decide whether the tank quietly does its job for you or keeps giving you problems that look like tank faults and are not.
This article will not turn you into a plumber. It gives you a map, so you can follow what your installer is doing, ask the right questions and check the work before anything gets buried. Our precast concrete tanks come with inlet and outlet openings that connect to mains, a water truck, a well or a pump. Everything beyond that depends on your pipework.
The five connections at a glance
Any storage tank needs a way in, a way out, a way to stop filling, a way to get rid of excess, and a way for air to move.
| Connection | Position | Job | Common mistake |
|---|---|---|---|
| Inlet | Top of tank | Fills from mains, truck or well | Discharging near the floor |
| Outlet | Low, raised off the floor | Feeds the pump | Drawing from the floor itself |
| Float valve | End of the inlet line | Stops filling when full | No room for the arm to move |
| Overflow | Below the inlet level | Removes excess if the float fails | Narrower than the inlet |
| Vent | Top of tank | Lets air in as water drops | Left without a screen |
Inlet filling from the top
There are two reasons the inlet goes high. First, water falling from above leaves an air gap between pipe and surface, which stops stored water being drawn back into the supply if line pressure drops. Second, you can reach it through the lid when it needs attention.
With more than one source, give each its own clear entry point. Mains gets a valve and a float valve. The truck gets a capped filling point within hose reach, ideally so the truck never has to enter your yard. Our water truck filling guide covers that side in detail. A well line gets its own valve, and it is worth deciding early whether well water should mix with household water at all. Many owners keep one tank for the house and another for irrigation.
In Riyadh and plenty of other cities, homes fill from mains and fall back on trucks during outages. Build both routes on day one, even if you do not need the truck today.
Outlet low, but not on the floor
The outlet feeds your tank pump. It goes low so you can use most of the water, but it should not draw from the floor. Sediment that arrives with the water gradually settles there, and it should wait for the next tank cleaning rather than travel to your pump and water heaters.
That leaves a little water below the draw point, which is normal and intended. Fit a valve close to the tank, so you can repair the pump or a joint while the tank stays full.
Keep the run short and direct. If the tank is buried and far from the house, photograph the route before backfilling. Those photos will save a lot of digging later.
Float valve simple and often the culprit
A mechanical float valve is just a ball on an arm. As water rises, the arm closes the valve. As water drops, it opens again. Because it moves, it is the part most likely to need attention.
- Leave enough room so the arm never rubs a wall or the opening.
- Fit a stop valve before it, so you can swap it without shutting off the house supply.
- Adjust the arm so it closes before water reaches the overflow.
- Place it near the lid so you can reach it by hand.
Do not confuse it with the electric float or level sensor that protects your pump. That second device cuts power to the pump when the water gets low. They do different jobs and go in different places.
A float valve also does nothing for a truck delivery. The truck has its own inlet and someone has to watch the fill, which is one more reason the overflow matters.
Overflow your safety net
If a float sticks or a truck driver loses track, excess water needs somewhere known to go, rather than pushing at the lid and openings. Three points decide whether an overflow really works.
- It sits below the inlet. That preserves the air gap.
- It is at least as wide as the inlet. Otherwise it cannot carry away what comes in.
- It ends where you can see it. A visible discharge tells you the float has failed. A hidden one can waste water for a long time before anyone notices.
Never let it discharge beside your foundations or onto a neighbour. Fit a screen to keep out insects and rodents. For a buried tank in high groundwater, make sure nothing can back up through the overflow. This matters on low coastal ground such as Jubail and Jazan.
Vent and lid
When the pump draws water out, air has to replace it, or suction weakens. Point the vent downward and screen it. The lid should close firmly and lock, keeping out children, dust and surface water. On a buried tank, raise the rim of the opening above ground level so washing water and rain cannot run in.
How to connect two tanks
When the sums come out larger than one tank, connect two. We can install and connect several. For example, 40 residents at 250 litres per person use 10,000 litres a day. One 29 m³ tank gives just under 3 days and two give just under 6. Try your own numbers in the tank size calculator.
Balance pipe at the bottom
The common method is a pipe joining the tanks low down, so the water finds a single level. Fill one and the other rises with it. Draw from one and both drop. Put a valve on the balance line at each tank, otherwise you cannot empty one while keeping the other in service.
Shared suction line
Each tank has its own outlet and valve, and the two lines meet in one pipe going to the pump. This gives more control, since you can draw from either tank and close the other. It suits apartment buildings that cannot afford an interruption during cleaning.
Why matching heights matter
Water levels out by height, not by volume. Link a 22 m³ square tank, 3.00 m tall, with a 29 m³ wide tank, 3.30 m tall, on the same base level, and the shorter one reaches its top first and starts to overflow while the taller still has room. Part of what you bought goes unused. Two matching tanks, such as a pair of 24 m³ tanks, avoid the problem. Bases must also sit level with each other, which is one reason to read about preparing the site first.
The practical bonus is that you can clean one tank while the other keeps serving you. A single large tank cannot do that. For projects with several units, ask us for a special quote.
Pipes leaving a buried tank
The joint where a pipe leaves the tank deserves respect. The tank is heavy and stays put, while soil around the pipe may settle slightly after backfilling. A rigid pipe with no give can suffer at that joint. A careful installer allows some flexibility there and beds the pipe in fine material, not stones that press against it.
Do not backfill before testing. Fill the tank, check every joint and photograph it. A damp spot is easy to deal with now and painful once it is underground. If you suspect something later, our leak detection guide helps you separate a joint leak from other causes.
For a tank above ground the concern is different. Exposed pipes sit in the sun and heat the water inside them, so shade or wrap them. In places with cold winters such as Tabuk and Al Jouf, insulate exposed runs as well.
Order of work
- Fix the tank position and where its openings face relative to house and pump.
- Plan pipe routes, the mains arrival point and the truck filling point.
- Check crane and truck access so prepared pipes are not in the way.
- On installation day, connect once the tank is settled in place.
- Fill the tank and test float valve, overflow, valves and pump.
- Photograph everything, then backfill or cover the routes.
Sign-off checklist
- Every line is identified and you know where it starts and ends.
- The float valve closes before water reaches the overflow.
- The overflow ends somewhere visible and safe, with a screen.
- The outlet is raised off the floor and has a valve.
- The vent is screened and the lid locks.
- All joints are dry with the tank full.
Mistakes we see often
- New holes without asking. Some installers cut into a tank to save time. Speak to us first.
- Overflow into a hidden drain. You lose water without noticing until the meter tells you.
- Valves buried in backfill. Put them in a box you can open.
- Pump drawing from the supply line. It should always draw from the tank.
- Well and household water mixed by default. Decide early what each tank is for.
Next step
Send your location and site photos on WhatsApp through our contact page, and tell us how you plan to fill the tank and where the pump will go. We reply with a written quote and a date, wherever you are in Saudi Arabia. All sizes are on the tanks page.