On most farms, water storage grows by accident. A plastic tank here, a truck there, and a line from the well that cannot quite keep up with the irrigation. This guide puts some order into it how to measure what the farm really draws, how to turn that into a capacity, how to tie a farm water tank into your well and pumps, and where to place it so nothing lets you down at the worst point of the season.
You will not find a litres-per-palm figure here. Real demand depends on crop, soil, tree age, month and irrigation system, so any general number would be wrong for somebody. What you will get is a method that produces your own number, which is worth more.
Why a farm with a well still needs a tank
"I have a well, why would I need storage?" comes up a lot. A well is a source. A tank is a reserve. The difference shows up in daily work.
- The well runs at its own pace. Your network may want more per hour than the well can give. A tank collects steadily and lets you draw at whatever rate you need.
- Generator and irrigation hours come apart. Run the well pump when it suits you and irrigate from storage at another time.
- Breathing room when things fail. A pump dies in July and the trees will not wait. A reserve gives you time until the technician arrives.
- A protected supply for animals and housing. Irrigation can stop without drinking water stopping with it.
Measuring irrigation demand without guessing
There are two easy methods. Try both and compare.
Method one count the emitters. Trees × emitters per tree × emitter flow × hours run. The flow is marked on the emitter or on your supplier's sheet.
Here is an example with made-up numbers. 500 trees with 2 emitters each, at 8 litres an hour, running for 3 hours 500 × 2 × 8 × 3 = 24,000 litres, or 24 m³ per cycle. This is not a recommendation for your trees. Put your own figures in.
Method two read a meter or a level. With a meter on the irrigation line, read it before and after a cycle. Without one, if you have a tank with known dimensions, measure how far the level drops and multiply by the base area. That is your true draw.
The month matters more than people expect. Do not measure in winter. Work from your heaviest month, because that is when a shortage shows up in the crop. If you are unsure what schedule your crop needs, ask an agronomist. We can help with storage; they can help with the plants.
Livestock and staff housing
Animals do not fit a single rule, since drinking varies with species, age, heat and feed. So measure it. Count how many times you fill a trough on a summer day and multiply by its capacity, or fit a simple meter on the trough line. Unlike irrigation, this demand cannot wait, so it is the first thing to protect in your reserve.
Housing is easier because the 250 litre rule applies. Six workers use 1.5 m³ a day. For a farmhouse where family gather at weekends, size for the peak 20 people use 5 m³ in a single day, and if you host often, use the 350 litre rate. That part works just like the standard tank sizing guide.
From daily draw to tank capacity
Add the three figures to get your highest daily draw, then see how long each option lasts. The table below is simply capacity divided by demand.
| Daily draw | 14 m³ | 24 m³ | 29 m³ | Two tanks, 58 m³ | Three tanks, 87 m³ |
|---|---|---|---|---|---|
| 3 m³ | 4.7 days | 8 days | 9.7 days | 19.3 days | 29 days |
| 5 m³ | 2.8 days | 4.8 days | 5.8 days | 11.6 days | 17.4 days |
| 8 m³ | 1.8 days | 3 days | 3.6 days | 7.3 days | 10.9 days |
| 10 m³ | 1.4 days | 2.4 days | 2.9 days | 5.8 days | 8.7 days |
| 15 m³ | 0.9 days | 1.6 days | 1.9 days | 3.9 days | 5.8 days |
| 25 m³ | 0.6 days | 1 day | 1.2 days | 2.3 days | 3.5 days |
How many days do you need? Ask how long a failed well pump would really take to fix how long until the technician and the part reach you where you are. On a remote farm, that is usually longer than you first assume. That answer is your number. The table then lets you decide whether to cover everything, or just the essentials such as drinking water and your most sensitive crops.
When the well is weaker than the irrigation
This is the question that matters most on a farm, and the numbers answer it. First measure your well. Fill a barrel of known size and time it. If a 200 litre barrel fills in 2 minutes, the well gives 100 litres a minute, or 6 m³ an hour.
Now continue with the example above. A 24 m³ cycle over 3 hours means the network draws 8 m³ an hour. The well gives 6. Over those 3 hours it supplies 18 m³, leaving 6 m³ to come out of the tank if the well runs at the same time.
If you want the well off while you irrigate, the tank has to hold the full cycle, so at least 24 m³, and a 28 m³ tank gives you some margin. At 6 m³ an hour, a 29 m³ tank fills in just under 5 hours. So running the generator by day and irrigating at night or dawn becomes a simple timetable.
The same sum tells you something else whether your problem is storage or the well. If the well cannot supply your whole daily draw, no tank will fix that for long. You need to revisit the schedule or find a second source. Our tank pump guide explains the difference between filling and supply pumps.
Farms that rely on water trucks
Some farms have no well, or a salty or weak one, and top up by truck. That changes the logic. A truck arrives as one big delivery and your tank needs to take all of it, so size around your load. Also keep the tank near a track that can carry a loaded truck. Not every internal farm road can, especially after rain. See the water truck filling guide.
One tank or several?
On most farms, several, and not only for volume. You can site tanks by what they serve.
| Use | Where it goes | Size, depending on your sums |
|---|---|---|
| Farmhouse and staff housing | Near the housing, separate from irrigation | 14 m³ or 22 m³ |
| Main irrigation | Near the well and pump room | 29 m³ or two connected tanks |
| Livestock | Near the pens | 14 m³ or 24 m³ |
| A distant plot | At the far end with its own fill line | By that plot's draw |
Separation pays twice. A fault on the irrigation line does not stop the house, and you can clean the housing tank without touching irrigation. Well water may also differ from what you use at home, so be clear about where the housing supply comes from. See keeping tank water clean and the cleaning guide.
Where to place a tank on a farm
Space is rarely the issue on a farm. The usual error is choosing a spot that makes everything longer later.
- Close to the well and pump. Every extra metre of line means more work, more maintenance and more lost pressure.
- On high ground if you can. With a slope, use it. An above-ground tank on a base at a high point eases things for nearby troughs, though irrigation networks will usually still need a pump.
- Out of the flood path. Every landowner knows where water runs when it rains. Do not build a base in that channel, even if it has been dry for years.
- Clear of palms and large trees. For the sake of digging and the base, and because the crane needs room to stand and swing.
- Reachable by truck and crane. The tank comes by truck and is placed by crane, so the route must carry that weight. Read crane and delivery access and photograph the road end to end.
Footprint rarely limits you on a farm, but shape still counts. The 29 m³ long tank, only 2.50 m wide, runs well along a fence or beside a track. The 29 m³ wide tank, at 4.40 × 2.90 m, tucks into a corner by the pump room. All the options are on the tank sizes page.
Above ground or underground on a farm?
Both work, but what decides it on a farm is not what decides it at a villa.
Above ground on a base suits most farms. Land is available, no excavation is needed, connections stay visible and easy to inspect, and you get some height for nearby troughs. The base has to be level, compacted and stable, and the site preparation guide explains how.
Underground suits places where the surface has another use, or where you would rather not see the tank from the farmhouse. Keep it away from spots where irrigation water collects. Where groundwater is close to the surface, as in parts of Al Ahsa, excavation needs planning, so read about tanks in high groundwater. The full comparison is in underground versus above ground tanks.
Why concrete for farm storage
Plastic and fibreglass tanks have their place, particularly when you want something light to move, or a small tank for mixing. For the main reserve, these points matter.
- It stays put. Its weight keeps it in place in strong wind, even when empty.
- It suits working yards. A knock from farm equipment is much less of a worry.
- Large volume in one unit. Up to 29 m³ per tank, rather than many small ones to connect.
- Factory made. Cast and cured in our Riyadh factory under engineering supervision, so no pouring crew needs to camp on your farm.
- Two waterproofing layers. Water-safe chemical lining inside and bitumen outside, with a 10-year warranty on manufacturing and installation covering cracks and leaks.
For wider comparisons, see concrete versus fibreglass and concrete versus plastic.
Farming regions each bring their own question
Every region shifts the decision a little. These general points will help you ask the right things.
- Al Kharj and Qassim are major farming areas where most projects run on wells, so the well flow sum is your starting point.
- Hail, Al Jouf and Tabuk have cold winters and hot summers, so think about protecting exposed pipework in winter.
- Al Ahsa is palm and oasis land, with water close to the surface in many spots. Check before you dig.
- Jazan stays hot and humid all year, so attention to waterproofing and exterior connections pays off.
- Taif and Asir have terraces and mountain roads, so crane access comes before size.
- Najran has many farms on trucks or wells, where load size and reserve become the base of the calculation.
Larger agricultural projects
With several plots, greenhouses or big pens, stop thinking in single tanks and start thinking in sectors. Each sector has a daily draw, a tank or more, and a fill line. Start with what is running now and leave room to grow. A project drawing 40 m³ a day needs 80 m³ to cover two days, which means three 29 m³ tanks at 87 m³ in total. Split across two sectors, the third tank becomes the reserve for your most important sector.
We can install several tanks and connect them, and multi-tank orders and projects get a special quote. Have the project engineer plan inlet and outlet lines together with the pumps, and read tank plumbing and connections before trenching begins.
Simple checks that protect your season
Farm water carries sand and sediment, especially from wells, and that tends to hurt emitters more than the tank. So fit a filter on the outlet line and open it regularly. Inspect the tank before the hot season, not halfway through. Check openings and covers too, since farms mean dust and birds. If the level falls with no draw, read how to detect a tank leak before you blame the well.
What to send us for a quote
Farms rarely have a clear address, so a location pin comes first. Send these on WhatsApp.
- The farm's map location and photos of the road from the last paved point.
- Photos of the tank spot, and your water source well or truck.
- Your daily draw if you have worked it out, and how many tanks you expect.
- Whether you want tanks above ground on a base or underground.
We reply with a written quote and a date. The quote is free, with VAT shown separately and an official tax invoice. To learn how we work first, see about us and the FAQ.